BTQHS - PURPLE PRIMER

  • MSDS: BTQHS
  • Manufacturer: WILTIC CHEM
  • Product Name: PURPLE PRIMER
  • National Stock Number: 8010-00N046162
Product Identification

Product ID:PURPLE PRIMER
MSDS Date:02/05/1991
FSC:8010
NIIN:00N046162
MSDS Number: BTQHS

Responsible Party
WILTIC CHEM
7034 E COURT ST
DAVISON, MI 48423
US

Emergency Phone: 313-744-4500;800-535-5053

Info Phone: 313-744-4500

Cage: IO659

Contractor
WILTIC CHEM
DAVISON, MI 48423 US

Telephone: 313-744-4500

Cage: IO659

Ingredients

ACETONE (SARA III)

CAS: 67-64-1

RTECS: AL3150000

Fraction By Weight: 50%

OSHA PEL 750 PPM;1000 STEL

ACGIH TLV: 750 PPM;1000 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


2-BUTANONE; (METHYL ETHYL KETONE) (MEK) (SARA III)

CAS: 78-93-3

RTECS: EL6475000

Fraction By Weight: 40%

OSHA PEL 200 PPM;300 STEL

ACGIH TLV: 200 PPM;300 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


FURAN, TETRAHYDRO-; (TETRAHYDROFURAN) (SARA III)

CAS: 109-99-9

RTECS: LU5950000

Fraction By Weight: 10%

OSHA PEL 200 PPM;250 STEL

ACGIH TLV: 200 PPM;250 STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYE: SEVERE IRRIT & DISCOMFORT.
OVEREXP TO THE LIQ MAY CAUSE EYE CORROSION WITH CORNEA OR
CONJUCTIVAL ULCERATION. SKIN: MODERATE IRRITATION & DISCOMFORT
POSSIBLE. DEFATTING, REDNESS & CHEMICAL DERMATITIS POSSIBLE.
RECURRENT OVEREXP MAY CAUSE TOXIC SYSTEMIC EFTS. INHAL: NAUS, HDCH,
DIZZ, IMPAIRED(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: COORDINATION. SEVERE OVEREXP MAY
CAUSE LOSS OF CONSCIOUSNESS & RESPIRATORY TRACT IRRIT. TOXIC
SYSTEMIC EFFECTS ARE POSSIBLE W/RECURRENT OVEREXPOSURE. INGEST:
IRRIT & DISCOMFORT IS POSSIBLE.
Medical Cond Aggravated by Exposure:NO DATA FOUND.

First Aid

First Aid:EYE: REMOVE CONTACT LENSES IF APPROP. FLUSH W/PLENTY OF WATER
FOR AT LEAST 15 MIN. GET IMMED MED ATTN. SKIN: WASH EXPOSED AREA
WITH MILD SOAP AND WATER. GET MED ATTN IF IRRIT DEVELOPS OR
PERSISTS. INH AL: REMOVE TO FRESH AIR. IF UNCON, GIVEOXYGEN. IF NOT
BRTHG, APPLY ARTF RESP. GET IMMED MED ATTN. INGEST: GIVE 1-2
GLASSES OF WATER TO DILUTE & GET IMMED MED ATTN. DO NOT INDUCE
VOMIT (SUPP DATA)

Fire Fighting

Flash Point Method:TCC
Flash Point:-4F,-20C
Lower Limits:2%
Upper Limits:11.8%
Extinguishing Media:ALCOHOL FOAM, DRY CHEMICAL, CO2, WATER FOG. USE
WATER SPRAY FOR COOLING EXPOSED CONTAINERS.
Fire Fighting Procedures:EVAC AREA. FIRE FIGHTERS SHOULD WEAR NIOSH/
MSHA APPROVED SCBA AND FULL PROT EQUIP . WATER IN A STRAIGHT HOSE
STREAM MAY CAUSE FIRE TO SPREAD & (SUPP DATA
Unusual Fire/Explosion Hazard:FUMES ARE HEAVIER THAN AIR AND MAY TRAVEL
ALONG THE GROUND TO IGNITION SOURCES.

Accidental Release

Spill Release Procedures:AVOID CONTACT WITH LIQUID & VAPORS. EXTING ALL
POSSIBLE SOURCES OF IGNITION. VENTILATE AREA. SOAK UP ON ABSORBENT
MATERIAL FOR DISPOSAL. FLUSH SMALL SPILLS WITH LARGE AMOUNTS OF
WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:GOOD GENERAL VENT SHOULD BE PROVIDED
TO KEEP VAP CONCS BELOW FLAMM & EXPOSURE LIMITS. KEEP FROM HEAT,
SPARKS & FLAME.
Other Precautions:KEEP CNTNRS TIGHTLY CLSD WHEN NOT IN USE. STORE IN A
COOL, DRY, VENT AREA AWAY FROM IGNIT SOURCES. DO NOT STORE
W/OXIDIZING AGENTS. DO NOT INGEST. AVOID PROLONGED OR REPEATED
CONTACT WITH SKIN.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATORS IF VAPOR
CONCENTRATIONS EXCEED PERMISSIBLE EXPOSURE LIMITS.
Ventilation:USE LOC EXHST/DILUTION VENT AS REQUIRED TO CONTROL VAP
CONCS BELOW PERMISSIBLE EXPOSURE LIMITS. MECH EXHST IF(SUPP DATA)
Protective Gloves:PVA COATED/CHEM RESISTANT MATL.
Eye Protection:CHEM SPLASH GOGGS W/ SPLASH SHLDS/FFSHLD
Other Protective Equipment:TO PREVENT REPEATED OR PROLONGED SKIN
CONTACT, WEAR IMPERVIOUS CLOTHING.
Work Hygienic Practices:WASH SKIN AND CLOTHING THOROUGHLY AFTER
HANDLING.
Supplemental Safety and Health
FIRE FIGHT PROC:SHOULD BE USED FOR COOLING ONLY. FIRST AID PROC:
WITHOUT MED ADVICE AS ASPIR CAN CAUSE ASPHY. TETRAHYDROFURAN CAN BE
ABSORBED WITH AN ACTIVATED CHARCOAL SLURRY. NEVER GIVE ANYTHING BY
MOUTH TO AN UNCONSCIOUS PERSON. VENT: REQUIRED. SHOULD BE REMOVED
FROM THE VAP CONC OR BE OF AN EXPLO PROOF DESIGN.

Chemical Properties

HCC:F2
Boiling Pt:B.P. Text:133F,56C
Vapor Pres:133
Vapor Density:2.25
Spec Gravity:0.81
Evaporation Rate & Reference:9.9 (BUTYL ACETATE=1)
Solubility in Water:70% @ 20C
Appearance and Odor:PURPLE LIQUID WITH ODOR OF KETONES.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:PEROXIDES MAY FORM UPON AGING. DO NOT
DISTILL TO DRYNESS.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
HYDROGEN CHLORIDE AND VARIOUS HYDROCARBONS FROM INCOMPLETE
COMBUSTION.

Disposal

Waste Disposal Methods:COMPLY WITH FEDERAL, STATE AND LOCAL
REGULATIONS. IF PERMITS AND REGULATIONS ALLOWED, MAY BE
INCINERATED, ALLOWED TO EVAPORATE OR DEEP WELL INJECTED.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.